Indoor and outdoor small villa elevator, duplex loft, second, third and fourth floor traction lift, home elevator

Facebook
Twitter
LinkedIn

Traction elevator

Elevator number: T1
Product Name : villa elevator
Product Model: HJY 0.4​
Rated speed : 0.4 m / s
Rated full load : 400kG​
Number of units: 1 unit
Number of floors : 2/2, 3/3, 4/4, 5/5, 6/6, 7/7
Base station : 1F
During a power outage Automatic floor stop during power outage 11kw ARD
Increase height: Based on actual measurements
Operation method: Complete Collection
Drive method : Traction type
Control method : VVVF Variable Frequency Speed Control
Drive power supply: Customizable power supply
Communication control : Serial communication
Car dimensions : 1200 mm wide x 1200 mm deep x 2000 mm high Based on actual measurements
Door opening dimensions: 80 0 * 2050 mm
Net dimensions of the space : 1900 mm wide x 1550 mm deep        Based on actual measurements
Top floor height : 300 0 mm
Pit depth : 300 mm
sedan chair

 

 

Box

Material of the hall door; 304 Stainless Steel Brushed Electric Door
Left side wall material: Rose gold / titanium /natural stainless steel
Material of the right side wall: Rose gold / titanium /natural stainless steel
Back wall material: Rose gold / titanium /natural stainless steel
Ceiling: Double layer
Car bottom: Powder coated steel plate / double layer
Car interior and exterior control boxes: Dot matrix display
Door security system : Light curtain protection system
Car lighting : Opple LED spotlights are installed on the car roof
Door opening method: Automatic, center parting

 

Main functions

Serial Number Function Name Function Description
1 Maintenance and Operation This is an operating function used during elevator maintenance or testing. When the operating conditions are met, pressing the up/down button will cause the elevator to move up/down at a maintenance speed. Holding down the button will keep the elevator running; releasing the button will stop it.
2 Direct docking Using the distance control principle, N operation curves are automatically generated based on parking requests to stop at the destination floor with optimal deceleration.
3 Self-rescue operation When the elevator is not in maintenance mode and is not stopped at the landing level, it will automatically move slowly to the landing level and open the doors to let passengers in, provided that the safety requirements for starting are met.
4 Infrared light curtain protection If there are obstacles blocking the doorway, the elevator will not operate to prevent accidents that could cause injury.
5 Overloaded vehicles are prohibited from operating. If the elevator is overloaded, the elevator doors will open, the overload indicator light will illuminate, the buzzer will sound, and the control panel will display “Overload”.
6 Running status display Displays elevator travel direction, floor information, operating status, and fault information.
7 Door interlock protection The elevator can only operate when all departmental interlocks are engaged; otherwise, the elevator will stop operating.
8 Main contactor protection The system continuously monitors the reliability of the main circuit contactor’s operation; if any abnormality is detected, operation is immediately stopped.
9 Brake detection and protection The opening and closing of the brake are monitored in real time via a brake arm detection switch. If the brake fails to open as required, the system will prevent startup.
10 Terminal speed switching protection When the elevator detects the terminal switch during operation, it will be forced to slow down and automatically correct the floor display.
11 Limit protection Once the limit switch is activated during elevator movement, the elevator will immediately stop moving up or down.
12 Limit protection Once the elevator reaches the limit switch and trips, the entire system will immediately stop and report a fault.
13 Elevator malfunctions and diagnosis When a fault occurs, the system can automatically diagnose the cause of the fault and display the fault information code.
14 Safety circuit protection If the safety circuit is disconnected, the elevator will stop operating immediately.
15 Energy-saving function of lighting fans If the elevator is not used within a specified time, the interior lighting and fan will automatically turn off to save energy.
16 Control cabinet floor selection The elevator can be registered internally and open/close commands can be entered via the LCD screen.
17 Button Embedded Self-Diagnosis If a call button is not disconnected within 20 seconds of being pressed, the system considers the button embedded, and will no longer register calls for that floor, while flashing an alarm. When the button is disconnected, the system exits this state ( optional ).
18 Emergency lighting In the event of a power outage, the system will automatically turn on the emergency lighting inside the car after a 15-second delay .
19 ARD ( Automatic Leveling Device ) When a power outage occurs during elevator operation, ARD quickly provides backup power, allowing the elevator to move to the nearest floor and ensuring passengers can safely evacuate.
20 Repeatedly opening the door If the elevator door remains closed for a certain period of time, the door will automatically open.
twenty one Test Function By setting parameters, the elevator can be made to run automatically to test whether the elevator is operating normally.
twenty two Optimal curve automatic generation During operation, the elevator uses fuzzy calculation and memory functions to select the most efficient acceleration and stopping methods, thereby improving operating efficiency.
twenty three Short circuit detection to ground When powered on, the system can automatically detect whether the motor is short-circuited to ground.
twenty four Pre-torque setting The pre-torque at motor startup can be set separately.
26 Complete Collection The elevator responds to both in-car commands and external calls automatically. It can be summoned from any floor using a call button (and during operation, it can respond to all commands and calls in the correct direction).
27 Door lock short circuit test If the elevator is running automatically (normally) and a short circuit is detected in the door lock after the door has opened to the correct position, the system will issue an alarm.
28 Anti-slip protection When not under maintenance, if the elevator is detected not leveling within a set time, the system will automatically protect itself and stop operating.
29 Contactor adhesion protection function If the contacts fail to open after the contactor coil loses power, the elevator must not be restarted to ensure safety.
30 Fault restart function

 

A restart function resolves various faults or maintenance statuses. Only after the fault has been cleared, the switch is moved to the running position, and power is restored can the equipment operate normally, preventing misoperation and ensuring safety and reliability.

 

 

 

 

 