SJD Series Hydraulic Lifting Work Platform
Instruction Manual
- Overview
The guide rail type hydraulic lifting platform is a non-scissor type hydraulic lifting platform used for transporting goods in industrial plants, restaurants, and hotels with two or more floors. With a minimum height of only 150-300mm, it is ideal for confined spaces where digging a pit is not possible or the top floor height cannot meet requirements. It requires no upper adjustment point and is available in various forms (single-column, double-column, four-column). It features smooth operation, simple and reliable operation, and economical and easy hydraulic and electrical cargo transport. (Specific load capacity, number of floors, and dimensions can be designed and manufactured according to user requirements.)
Jinan Yongli Machinery Co., Ltd. will do its utmost to tailor a high-efficiency delivery platform for you. The product’s hydraulic system features operation buttons on each floor and the lifting platform’s work surface, enabling multi-point control. The product boasts a robust structure, high load capacity, smooth lifting, and simple and convenient installation and maintenance, making it an economical and practical alternative to elevators for transporting goods between low floors. Different optional configurations can be selected based on the installation environment and usage requirements of the lifting platform to achieve better results.
- Maximum load capacity of 20 tons (load capacity can be customized or higher), enabling multi-point control;
- High lifting height, using side-mounted or double-sided hydraulic cylinders, smooth operation, low noise, convenient maintenance, and long service life;
- Manual descent during power outages and an emergency stop button make it convenient, quick, and practical;
- The floor doors can be connected, allowing the inside and outside of the factory to be opened to each other, which is convenient and saves space;
- Particularly suitable for 2-6 story steel structure factory buildings, can be used both internally and externally;
- The pump station adopts a joint venture pump station. If the speed requirement is too high, an imported customized pump station is used to achieve the ideal delivery requirements. It also has a mechanical emergency lowering device that can be opened in case of power failure or emergency, and the platform can automatically fall back to the bottom.
- Imported components are used for the cylinder and seals to solve the problems of unstable oil pressure and oil leakage in the parts.
Advantages of civil engineering:
- No machine room is required above the shaft; installation is possible with a top floor height of 3.5 meters or more.
- The hydraulic pump station or control system can be installed within a radius of 15 meters of the shaft, occupying only 2-4 square meters of area;
- The lifting platform does not have a counterweight device, which improves the utilization rate of the shaft area;
- The load and weight of the lifting platform are directly applied to the pit through the hydraulic cylinder. The strength requirements of the shaft are low. A brick structure or brick-concrete structure shaft is sufficient. In special cases, it can also be installed and used even if there is no shaft but only an opening.
Safety and stability advantages :
In addition to the safety devices of traditional traction elevators, the lifting platform also features:
- Relief valve: Prevents excessive system pressure during upward movement;
- Emergency manual valve (optional): In case of power failure, the car can be lowered to the nearest floor to open the door. The pump station is equipped with a mechanical emergency lowering device, which can be opened in case of power failure or emergency, and the platform can automatically fall back to the bottom floor.
- Manual pump (optional): In case of system failure, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor;
- Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car descends uncontrollably, it can automatically cut off the oil circuit to stop the descent;
- Oil tank temperature protection (optional): When the oil temperature in the oil tank exceeds the standard setting value, the oil temperature protection device will send a signal to suspend the use of the elevator. The elevator can be started only after the oil temperature drops. Alternatively, an oil temperature constant cooling system can be installed to keep the platform running without being affected by the oil temperature.
- Low failure rate: Thanks to the adoption of an advanced hydraulic system and a good control method, the failure rate of the hydraulic lifting platform can be minimized.
- Low power consumption: When the hydraulic elevator descends, it is driven by the pressure generated by its own weight, which saves a lot of energy. The optional bidirectional oil cylinder can help provide the speed of ascent and descent.
Reference parameters for some products:
| model | Lifting stroke (mm) | minimum height
(mm) |
Load capacity
(Kilogram) |
Countertop size
(Length * Width in mm) |
motor power
(kw) |
| SJD0.3-4.5 (1st to 2nd floors) | 4500 | 150 | 300 | 1000×800 | 1.5 |
| SJD0.5-4.5 (1st to 2nd floors) | 4500 | 150 | 500 | 1500×1000 | 1.5 |
| SJD1.0-4.5 (1st to 2nd floors) | 4500 | 150 | 1000 | 1500×1500 | 3.0 |
| SJD2.0-4.5 (1st to 2nd floors) | 4500 | 150 | 2000 | 2000×1000 | 3.0 |
| SJD3.0-4.5 (1st to 2nd floors) | 4500 | 160 | 3000 | 2000×1200 | 3.0 |
| SJD0.3-7.5 (Floors 1 to 3) | 7500 | 150 | 300 | 1000×1000 | 1.5 |
| SJD0.5-7.5 (1st to 3rd floors) | 7500 | 150 | 500 | 1200×1200 | 1.5 |
| SJD1.0-7.5 (Floors 1 to 3) | 7500 | 150 | 1000 | 1800×1400 | 3.0 |
| SJD2.0-7.5 (Floors 1 to 3) | 7500 | 150 | 2000 | 2000×1500 | 4.0 |
| SJD3.0-7.5 (Floors 1 to 3) | 7500 | 160 | 3000 | 2000×1600 | 3.0 |
| SJD1.0-10.5 (Floors 1 to 4) | 10500 | 150 | 1000 | 1800×1400 | 4.0 |
| SJD1.0-14 (Floors 1 to 5) | 14000 | 150 | 1000 | 1800×1500 | 4.0 |
| SJD3.0-4.5 (Car Lift Specific) | 4500 | 160 | 3000 | 5000×3000 | 4.0 |
- Brief Introduction to Usage
All guide rail type hydraulic lifting platforms (hereinafter referred to as platforms) have been inspected and tested before leaving the factory, and all technical indicators have met the design requirements. Users only need to operate according to the steps; non-professionals are not allowed to adjust the hydraulic and electrical systems.
- When using the platform for the first time (or after long-distance transportation), carefully inspect the hydraulic and electrical systems to ensure there are no leaks or loose wiring before use.
- For platforms that have not been used for a long time, run them empty 1-3 times before loading jobs.
- The center of gravity of the load should be located at the center of the worktable surface;
- Work can only be carried out after the movable door of the work platform guardrail is closed and locked securely.
The platform’s hydraulic and electrical control systems, control methods, and operating procedures are described below for reference during operation:
- Support Valve Control System (or Imported Hydraulic Station Control System): This system controls the lifting and lowering of the platform through the opening and closing of solenoid valves. The electrical system is self-locking. During operation, power is connected, and the “Lift” button is pressed. The motor starts, the hydraulic system operates, and the platform lifts. After reaching the set height, the limit switch activates, and the platform stops at the set height. During lifting, the “Stop” button can be pressed at any time to stop the platform from lifting. After operation, pressing the “Lower” button engages the solenoid, actuates the solenoid valve, and lowers the platform. After lowering to the original height, pressing the “Stop” button disconnects the solenoid power. This control method does not have a manual lifting device. In the event of a power outage, the platform can be lowered by manually pushing the lever (or using a return oil knob in the imported system) to return oil to the system.
- Electro-hydraulic Directional Valve Control System: This system is used to control the platform of a large-displacement oil pump. The platform’s lifting and lowering are achieved by controlling the oil valve with an electromagnetic directional valve. The operating steps are as follows: First, open the suction pipe ball valve, close the system descent shut-off valve (rotate clockwise), connect the power supply, and press the “Lift” button. The lifting solenoid is energized, the motor drives the oil pump to rotate, and the platform rises. After reaching the desired position, the limit switch operates, the contactor is de-energized, the motor stops, and the platform stops at the working position. During the lifting process, the “Stop” button can be pressed at any time to stop the platform at any height. After work is completed, press the “Lower” button. The lowering solenoid is energized, the motor rotates, the hydraulic single-piece valve opens, the system returns oil, and the platform descends. After reaching the lowest position, the lower limit switch operates, the contactor is de-energized, and the motor stops. During the descent, the stop button can be pressed to stop the platform at any height. In case of power failure or if the platform does not descend, the system shut-off valve can be opened (rotate counterclockwise) to lower the platform.
III. Precautions for Guide Rail Type Hydraulic Lifting Platform
- Overloading and carrying passengers are strictly prohibited.
- Loading or unloading is strictly prohibited until the platform has come to a complete stop.
- After a platform malfunctions, it must not be used until the malfunction is resolved; at the same time, a sign prohibiting use should be prominently displayed next to the platform.
- Do not drag objects outwards forcefully while performing the task.
- Please do not sit, lie down, stand, or climb on the platform railings.
- Standing or placing objects under the lifting platform is strictly prohibited.
- Do not use this machine under any foreseeable dangerous conditions.
- Safety Operating Procedures for Guide Rail Type Hydraulic Lifting Platform:
- Before using this equipment, you must carefully read the instruction manual and maintenance safety instructions;
- The user unit should assign a dedicated person to operate the lifting platform and formulate detailed usage instructions and safety precautions for the lifting platform based on its own circumstances, and post these instructions in a prominent location. Operators must undergo training and assessment before they can operate the lifting platform;
- Before starting work each day, the operator must carefully check whether the platform’s electrical system, hydraulic system and mechanical system are normal, and run the platform up and down unloaded several times to check for any faults or abnormal phenomena. The operator must also pay attention to whether there are any obvious abnormal differences in the accuracy of the platform’s stopping points.
- Before starting work, the operator must ensure that the movable doors at both ends of the guardrail are securely closed and locked. Lifting or lowering operations are strictly prohibited with the guardrail doors open. In case of special circumstances during platform operation, the emergency stop switch can be used to stop the platform; however, during normal operation, the emergency stop switch must not be used to stop the platform.
- Operators are responsible for ensuring that the goods being transported on the platform are distributed as evenly as possible to prevent uneven loading, and overloading is prohibited. Flammable, explosive, or other dangerous goods are prohibited from being transported on the platform. During operation, it is strictly forbidden to carry people or allow any personnel to approach the platform’s lifting and lowering area.
- Operators are strictly prohibited from leaving their posts or performing wiping, lubrication, or repair work on the platform while it is in operation. Upon completion of work, the operator must disconnect the power, lock the control panel, and fill out the shift handover record.
- If the platform malfunctions or fails to operate normally, maintenance personnel should be notified immediately. If any danger or potential personal injury or mechanical failure is found, use should be stopped immediately, the main power supply to the computer room should be cut off, and the management department should be notified. The platform can only be used after repair and a detailed inspection.
- Daily Maintenance and Upkeep of Guide Rail Type Hydraulic Lifting Platform
- After completing the operation, the platform should be returned to the stopped transport state and the power supply should be disconnected;
- Prevent rainwater erosion;
- This equipment should be operated and maintained by designated personnel;
- Regularly check the lubrication of the hinge parts and add lubricating oil in time to prevent dry friction.
- The pin should be lubricated frequently and the bolt fixing points should be checked regularly. If any are loose, tighten the bolts before normal use.
- For newly commissioned platforms, the hydraulic oil should be changed after the first two months of operation. Subsequent changes can be made as needed based on operating conditions. Oiling tools should be kept clean, and the oil pump suction screen should be cleaned regularly. Hydraulic oil should generally be changed every six months. Use N32 anti-wear hydraulic oil in winter and N46 anti-wear hydraulic oil in summer.
- If oil leakage is found in the hydraulic cylinder, contact after-sales service. After verification by relevant technicians, the sealing ring should be replaced in time.
- When replacing hydraulic components, the components should be cleaned thoroughly. For components that cannot be assembled temporarily, the ports should be sealed to prevent collisions and debris from entering the oil circuit system.
- When cleaning hydraulic components, it is strictly forbidden to use cotton or other fabrics with easily detachable fibers.
- Common Hydraulic System Faults and Troubleshooting Methods (See attached table)
| Fault phenomenon | reason | Elimination methods |
| Oil cylinder leak | Hydraulic cylinder seals worn or malfunctioning | Replacement of parts and seals |
| Hydraulic cylinder descends | Foreign objects inside the solenoid valve, poor sealing | Disassemble and clean the solenoid valve and replace components |
| Pressure decrease | Oil suction port blocked, oil pump inlet loose, air leak | Clean the oil suction port and tighten the oil inlet seal. |
| Descent failure | Solenoid valve malfunction | Replace the solenoid valve |
VII. Accompanying technical documents (subject to the final actual situation)
- Product certificate of conformity; 2. Warranty card; 3. Instruction manual.

Troubleshooting and troubleshooting of hydraulic lifting platforms and pump stations
| Fault | Causes | Elimination methods |
| The pump station is not pumping oil (the platform is not rising). | 1. The motor (25) power supply is abnormal (loose connection) or reverses.
2. The oil tank (01) has no hydraulic oil or the oil level is insufficient. 3. The oil filter (06) is severely clogged. 4. Normally closed valve (17) dirty 5. The normally closed valve (17) and the motor (25) are energized simultaneously. 6. The pressure regulating valve (21) is set with insufficient pressure. 7. Gear pump (21) has insufficient set pressure. 8. Hydraulic oil aging and deterioration 9. Emergency bolt (19) was not tightened. 10. The connection between the oil suction pipe (07) and the gear pump (08) is loose and leaking air. |
1. Correctly connect the motor (25) power supply or adjust the direction of rotation.
2. Add hydraulic oil 3. Clean the oil filter (06) or replace the hydraulic oil. 4. Remove the normally closed valve (17) and clean it with cleaning agent or kerosene. 5. Connect the wires correctly. When the motor (25) is energized, the normally closed valve (17) is de-energized. 6. Adjust the pressure valve (21) 7. Replace the gear pump (08) 8. Change the hydraulic oil 9. Tighten the emergency valve (19) 10. Tighten the oil suction pipe (07) |
| The pump station is not returning oil (the platform is not descending). | 1. The normally closed valve (17) is not powered on or the voltage is insufficient.
2. The voltage and voltage type of the normally closed valve coil (17b) do not match the voltage and voltage type of the power supply. 3. Burnout of normally closed valve coil (17b) 4. The back cap (17c) of the normally closed valve is loose. 5. Close the speed control valve (23). 6. Normally closed valve (17) stuck. |
1. Connect the wires correctly and check the voltage.
2. Check the voltage and voltage type (AC or DC) to ensure that the power supply voltage and type match the voltage required by the normally closed valve coil. 3. Replace the normally closed valve coil (17b). 4. Tighten the back cap of the normally closed valve (17c). 5. Open the descent speed control valve (23) 6. Remove the normally closed valve (17) and clean it. |
| Platform decline | 1. The normally closed valve (17) is dirty or the check valve (15) is dirty.
2. Emergency bolt (19) was not tightened. 3. Oil leakage in the oil circuit or internal leakage in the oil cylinder |
1. Remove the normally closed valve (17) or check valve (15) for cleaning or replacement.
2. Tighten the emergency bolt (19) 3. Inspect and repair the oil circuit and oil cylinder. |
| flat
tower Lift drop No flat stable |
1. Normally closed valve (17) dirty
2. The oil filter (06) is clogged or the oil suction pipe (07) is loose. 3. The hydraulic oil is deteriorated or the oil level is insufficient. 4. The power cord is too long. 5. Emergency bolt (19) was not tightened. 6. The platform’s descent speed is too fast or too slow. 7. The hydraulic cylinder creeps due to air leakage in the pipeline. 8. The hydraulic cylinder creeps due to deformation or an overly tight seal. |
1. Clean the normally closed valve (17)
2. Clean the oil filter (06) to remove blockages or tighten the oil suction pipe (07). 3. Replace the hydraulic oil or add enough hydraulic oil. 4. Shorten the power cord 5. Tighten the emergency bolts (19) 6. Adjust the descent speed control valve (23) 7. Inspect and treat the pipelines 8. Replace the hydraulic cylinder or replace the hydraulic cylinder seals. |